Some racadm commands to help in configuring our DELL servers taken from a gist that I dont recall at the moment…

disable host -> BMC config update

racadm config -g cfgRacTuning -o cfgRacTuneLocalConfigDisable 1

disable dell proprietary admin protocol

(this won’t disable sshd or the internal racadm tool on the ssh shell)

racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 0

disable http/https server

racadm config -g cfgRacTuning -o cfgRacTuneWebServerEnable 0

disable IPMI Serial Over LAN

racadm config -g cfgIpmiSol -o cfgIpmiSolEnable 0
racadm config -g cfgIpmiPef -o cfgIpmiPefEnable 0 -i 1

disable ipmi trap

racadm config -g cfgIpmiPet -o cfgIpmiPetAlertEnable 0 -i 1

disable snmpd

racadm config -g cfgOobSnmp -o cfgOobSnmpAgentEnable 0

disable telnetd

racadm config -g cfgSerial  -o cfgSerialTelnetEnable 0

enable sshd

racadm config -g cfgSerial -o cfgSerialSshEnable 1

disable IPMI over LAN (globally, hopefully disables the ipmi server)

racadm config -g cfgIpmiLan -o cfgIpmiLanAlertEnable 0
racadm config -g cfgIpmiLan -o cfgIpmiLanEnable 0

reset the drac to make sure all settings apply